MANUFACTURER OF INDUSTRIAL INDUCTION BOILERS AND ELECTRIC BOILERS FOR HEATING AND DHW IN KAZAKHSTAN

Fill out the terms of reference

Tank Heating

Heating of various liquids in tanks is a common task in industry. Oil and oil products, water and other substances need heating and maintaining fluidity. This process can be carried out with high efficiency in a completely autonomous mode by using the Termanik induction boilers.
Made to order
Details

Industrial enterprises often face challenges associated with heating liquids in tanks. These can be tanks for:

  • fire, technical, drinking water;
  • oil and oil products;
  • various chemical liquids.

Подогрев в резервуарах предусматривается для поддержания текучести жидкости вне зависимости от температуры окружающей среды.

Heating of tanks is to maintain fluidity of a material inside it regardless of the environment temperature.
One of the effective ways of heating tanks is the applying of indirect heating systems based on inductive-conductive electric boilers Termanik.
This system involves a spiral or coil type heat exchanger inside the tank and “Termanik” induction boiler, which heats the heat-transfer fluid (water or antifreeze) up to 90-115°С / 190-240°F in an autonomous mode.

Specification
Heater power:
Termanik Complex 50
Rated Electric Power 50 kW
Heat Output 0.043 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 320 kg
Termanik Complex 50 (2×25)
Rated Electric Power 50 kW
Heat Output 0.022 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 150 kg
Termanik Complex 75
Rated Electric Power 75 kW
Heat Output 0.065 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 380 kg
Termanik Complex 75 (3×25)
Rated Electric Power 75 kW
Heat Output 0.065 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 400 kg
Termanik Complex 75 (3×25)
Rated Electric Power 75 kW
Heat Output 0.065 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 400 kg
Termanik Complex 100
Rated Electric Power 100 kW
Heat Output 0.086 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 420 kg
Termanik Complex 100 (2×50)
Rated Electric Power 100 kW
Heat Output 0.086 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 580 kg
Termanik Complex 125
Rated Electric Power 125 kW
Heat Output 0.108 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 450 kg
Termanik Complex 150
Rated Electric Power 150 kW
Heat Output 0.129 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 830 kg
Termanik Complex 150 (2×75)
Rated Electric Power 150 kW
Heat Output 0.129 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 880 kg
Termanik Complex 150 (3×50)
Rated Electric Power 150 kW
Heat Output 0.129 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 850 kg
Termanik Complex 200 (2×100)
Rated Electric Power 200 kW
Heat Output 0.172 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 810 kg
Termanik Complex 250
Rated Electric Power 250 kW
Heat Output 0.210 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 980 kg
Termanik Complex 250 (2×125)
Rated Electric Power 250 kW
Heat Output 0.210 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 980 kg
Termanik Complex 300 (2×150)
Rated Electric Power 300 kW
Heat Output 0.258 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 1100 kg
Termanik Complex 300 (3×100)
Rated Electric Power 300 kW
Heat Output 0.258 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 1100 kg
Termanik Complex 500 (2×250)
Rated Electric Power 500 kW
Heat Output 0.420 Gcal/h
Rated Voltage 380 V
Current Frequency 50 Hz
Current Phase 3
Electrical Safety Class 2
Power Factor (Cos φ) 0.98
Net Weight (without water) 1890 kg
Documentation:

Терманик каталог оборудования для нагрева резервуаров и емкостей в Казахстане Терманик Комплекс декларация соответствия  Терманик декларация соответствия Патент ТерманикСертификат ИСО ISO

Delivery set

Product configuration and delivery set may vary according to the customer’s requirements and a specific task

Терманик Комплекс схема

Мы используем cookie-файлы для наилучшего представления нашего сайта. Продолжая использовать этот сайт, вы соглашаетесь с использованием cookie-файлов.
Принять
Отказаться